Find Product:

Rat IL-1R1(Interleukin 1 Receptor Type I) ELISA Kit
E-EL-R2438-192
Elabscience Biotechnology 192 tests
Description: This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat IL-1R1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat IL-1R1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat IL-1R1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat IL-1R1. You can calculate the concentration of Rat IL-1R1 in the samples by comparing the OD of the samples to the standard curve.
Rat IL-1R1(Interleukin 1 Receptor Type I) ELISA Kit
E-EL-R2438-96
Elabscience Biotechnology 96 tests
Description: This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat IL-1R1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat IL-1R1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat IL-1R1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat IL-1R1. You can calculate the concentration of Rat IL-1R1 in the samples by comparing the OD of the samples to the standard curve.
Mouse Interleukin 1 Receptor Type I (IL-1R1) CLIA Kit
abx195875-96tests
Abbexa 96 tests
Mouse IL-1R1(Interleukin 1 Receptor Type I) ELISA Kit
E-EL-M0017-192
Elabscience Biotechnology 192 tests
Description: This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse IL-1R1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse IL-1R1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse IL-1R1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse IL-1R1. You can calculate the concentration of Mouse IL-1R1 in the samples by comparing the OD of the samples to the standard curve.
Mouse IL-1R1(Interleukin 1 Receptor Type I) ELISA Kit
E-EL-M0017-96
Elabscience Biotechnology 96 tests
Description: This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse IL-1R1. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse IL-1R1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse IL-1R1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse IL-1R1. You can calculate the concentration of Mouse IL-1R1 in the samples by comparing the OD of the samples to the standard curve.
Mouse IL-1R1 (Interleukin 1 Receptor Type I) CLIA Kit
E-CL-M0016-192
Elabscience Biotechnology 192 tests
Description: This CLIA kit uses the Sandwich- CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse IL-1R1 . Standards or samples are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse IL-1R1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse IL-1R1 , biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse IL-1R1 . You can calculate the concentration of Mouse IL-1R1 in the samples by comparing the RLU value of the samples to the standard curve.
Mouse IL-1R1 (Interleukin 1 Receptor Type I) CLIA Kit
E-CL-M0016-96
Elabscience Biotechnology 96 tests
Description: This CLIA kit uses the Sandwich- CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse IL-1R1 . Standards or samples are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse IL-1R1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse IL-1R1 , biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse IL-1R1 . You can calculate the concentration of Mouse IL-1R1 in the samples by comparing the RLU value of the samples to the standard curve.
Mouse IL-1R1(Interleukin 1 Receptor Type I) ELISA Kit
EM1160
FN Test 96T
Description:
  • Method of detection: Double Antibody, Sandwich ELISA
  • Reacts with: Mus
  • Sensitivity: 56.25pg/ml
ELISA kit for Rat IL-1R1 (Interleukin 1 Receptor Type I)
E-EL-R2438
Elabscience Biotech 1 plate of 96 wells
Description: A sandwich ELISA kit for quantitative measurement of Rat IL-1R1 (Interleukin 1 Receptor Type I) in samples from Serum, Plasma, Cell supernatant
ELISA kit for Mouse IL-1R1 (Interleukin 1 Receptor Type I)
E-EL-M0017
Elabscience Biotech 1 plate of 96 wells
Description: A sandwich ELISA kit for quantitative measurement of Mouse IL-1R1 (Interleukin 1 Receptor Type I) in samples from Serum, Plasma, Cell supernatant

Did not find what you were looking for? Send us request and we will contact with you!