GENTAUR Belgium BVBA BE0473327336 Voortstraat 49, 1910 Kampenhout BELGIUM Tel 0032 16 58 90 45
GENTAUR U.S.A Genprice Inc,Logistics 547 Yurok Circle, SanJose, CA 95123
Tel (408) 780-0908, Fax (408) 780-0908, sales@genprice.com

Index / Bioner / AccuPower Calibration Kit for ExicyclerTM 96 Real-Time PCR / Product Detail : A-2060-A1 AccuPower Calibration Kit for ExicyclerTM 96 Real-Time PCR
Related keywords:

Nov
16th

#A-2060-A1 AccuPower Calibration Kit for ExicyclerTM 96 Real-Time PCR

Ask technical file .

  Price : 1517   EUR
1722   USD
1176   GBP
6372   Zloty
202972   JPY
11698   NOK
12535   SEK
1715   CHF

Product name : AccuPower Calibration Kit for ExicyclerTM 96 Real-Time PCR

Catalog number : A-2060-A1

Quantity:

Availability: Yes

Supplier name : Bioner

ask pdf gentaur products Data sheet: Ask more or other datasheet now !

About this Product :

AccuPower Calibration Kit for ExicyclerTM 96 Real-Time PCR PCR kit use certain PCR kits can be used for diagnostics. We supply CE approved PCR kits or research PCR kits. You can request more information about the use of AccuPower Calibration Kit for ExicyclerTM 96 Real-Time PCR to info@gentaur.com
http://mybiofast.com/ver.php?search=pcr&submit=Search

More Details about

 


Exicycler96

Exicycler™ 96 is a superior 96-well PCR system designed for real-time qPCR applications demanding the highest performance. Proprietary Light Tunnel (LT) Technology mitigates the common problem of uneven light distribution across the 96-well plate, allowing for normalization of fluorescence signals from all five channels without the use of a reference dye. The instrument is also equipped with a thermal gradient function, allowing for convenient PCR condition optimization experiments. The analysis software contains several different modules for analyzing qPCR data including: Absolute Quantification, Relative Quantification, SNP genotyping, Existence/Nonexistence and melting curve analysis. With the various modules analyses such as viral load monitoring, gene expression analysis, SNP genotyping etc. can be performed. In vitro diagnostic software packages have also been developed (KFDA, CE-IVD certified versions), which allows the instrument to be used for molecular diagnostic purposes.






Applications

 Viral load
 Pathogen Detection
 Oncology
 Genetic disease detection
 Drug resistance analysis
 DNA methylation study
 SNP (Single nucleotide polymorphism) Detection
 Quantification of Gene Expression

fig2 


Benefits

 Even illumination with LT (Light Tunnel)Technology
LT delivers accurate and precise results without the need for a reference dye.

 Real 5-color multiplexing
Five band-pass filters each for excitation and emission are included for multiplexing, and since no reference dyes are necessary, true five-color multiplexing is possible.

 Real-time analysis
Use the Melting curve analysis module to measure the melting points of amplicons in real-time.

 Fast and accurate analysis
The high-performance 2D CCD sensor collects information from all 96 wells simultaneously, removing any detection-lag deviations and producing accurate results.

 Temperature Gradient function
Enabling the temperature gradient function allows a 1~20°C temperature gradient across the plate within 40~75°C, making it easy to find the optimal annealing temperature.

 Touch Down PCR
Time increments and temperature increment controls allow for touch-down PCR applications.

 Use various fluorescent dyes
The light source provides even excitation from 480 to 680 nm, allowing the use of various fluorescent dyes.

 Wide, linear dynamic range
The dynamic range of detection is wide at over 109.

 Intuitive and convenient software
A user-centric GUI lets users design and analyze experiments with ease.



Features

 LT technology optics to remove well-to-well variation
To eliminate the well-to-well light intensity variation associated with other systems, Bioneer has designed proprietary, patented optics: Light Tunnel technology.

fig3


 Minimization of Ct values for maximized reproducibility
By implementing the in-house designed LT technology in the optics module, well-to-well signal variation has been virtually eliminated and reproducibility has been maximized. No matter which well the reaction occurs, the Ct values will be within 0.5.

fig4


 True 5-Color Multiplexing
Instruments with uneven excitation illumination must use a separate reference dye to normalize signal differences between wells, thus eliminating the usefulness of one fluorescence channel. Exicycler™ 96 does not need a reference dye, freeing all five channels for true 5 color multiplexing. The optics are designed to minimize dye interference, and long-wavelength dyes such as Cy5 can also be used thanks to the short-arc lamp light source, which emits even illumination throughout the visible spectrum. Filter sets for the most popular dyes are pre-installed, so you don’t need to worry about installing more filters.

fig5


 Simultaneous well measurement
The 2D CCD sensor measures all 96 wells simultaneously, eliminating detection lag between wells. Instruments that scan each well or by column have the inherent disadvantage of letting the reaction proceed while measuring, thus producing the undesirable effect of detection lag.

 High performance light source
The high performance short-arc lamp used in the optical module emits a brighter light compared to halogen lamps commonly used in comparable instruments. Brighter excitation means better sensitivity, and the inherent long life and light stability enable various wavelengths to be used for experiments.

 Self diagnostics
The software performs instrument diagnostics before each experiment, preventing run errors from occurring before the experiment and thus saving valuable samples and reagents from going to waste.

 Automatic Door Open/Close function
The loading door is motorized for automatic door opening and closing, adding convenience and flexibility, as the instrument can easily be incorporated into an automated workflow.

 Thermal Gradient function
The thermal gradient function allows for rapid cycle condition optimization, increasing the convenience. 

fig6
Figure 5. Gradient PCR

 Intuitive and full-featured software
A user-friendly interface provides convenience in all steps of the qPCR process including protocol setup, data analysis and result storage. Data analysis modules including Absolute Quantification, Relative Quantification, Existence /Nonexistence, SNP Genotyping and melting curve analysis are included standard for flexibility in data analysis.


Experimental Results

1) Viral load testing (Absolute Quantification) 2) Gene expression (Relative Quantification)
fig7 fig8
By inter olating the Ct value of samples on the standard curve, the actual quantities in amples are measured. The relative expression levels of a target gene are compared among different samples.
3) Pathogen detection (Existence/Nonexistence) 4) Mutation detection and personalized medicine (SNP Genotyping)
fig9 fig10
The existence and nonexistence of pathogenic viruses in samples are determined. Two types of homozygote and the heterozygote are determined for a SNP site.
5) Melting curve analysis  
fig11  
Simple dissociation curve data collection and viewing

 

Contact us about this product :

Our team will respond you as soon as possible !

Email :
Skype :
Name :
Phone :
address :
Question, Comment ... :
arrow security gentaurPlease retype this code below:
Bioner \ AccuPower_Calibration_Kit_for_ExicyclerTM_96_Real_Time_PCR \ A_2060_A1
Reload Image

 

GENTAUR Belgium BVBA BE0473327336
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45

Fax 0032 16 50 90 45
info@gentaur.com | Gentaur | Gentaur





GENTAUR Ltd.
Unicorn House, Station Cl
Hertfordshire, Potters Bar EN6 1TL
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
uk@gentaur.com | Gentaur | Gentaur

 

 




GENTAUR France SARL
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50

Fax 01 43 25 01 60
RCS Paris B 484 237 888

SIRET 48423788800017
RIB 30004 00187 00010092253 10
BNP PARIBAS PARIS PL MAUBERT BIC BNPAFRPPPRG
IBAN FR76 3000 4001 8700 0100 9225 310
france@gentaur.com | Gentaur | Gentaur

GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Support Karolina Elandt
Tel: 0035929830070
Fax: (+49) 241 56 00 47 88

Logistic :0241 40 08 90 86
Bankleitzahl 39050000
IBAN lautet DE8839050000107569353
Handelsregister Aachen HR B 16058
Umsatzsteuer-Identifikationsnummer *** DE 815175831
Steuernummer 201/5961/3925
de@gentaur.com | Gentaur | Gentaur

GENTAUR U.S.A
Genprice Inc, Logistics
547, Yurok Circle
San Jose, CA 95123
CA 95123
Tel (408) 780-0908,
Fax (408) 780-0908,
sales@genprice.com

Genprice Inc, Invoices and accounting
6017 Snell Ave, Ste 357
San Jose, CA 95123




GENTAUR Nederland BV
NL850396268B01 KVK nummer 52327027
Kuiper 1
5521 DG Eersel Nederland
Tel:  0208-080893  Fax: 0497-517897
nl@gentaur.com | Gentaur | Gentaur
IBAN: NL04 RABO 0156 9854 62   SWIFT RABONL2U






GENTAUR Spain
tel:0911876558
spain@gentaur.com | Gentaur | Gentaur






ГЕНТАУЪР БЪЛГАРИЯ
ID # 201 358 931 /BULSTAT
София 1000, ул. "Граф Игнатиев" 53 вх. В, ет. 2
Tel 0035924682280 Fax 0035924808322
e-mail: Sofia@gentaur.com | Gentaur | Gentaur
IBAN: BG11FINV91501014771636
BIC: FINVBGSF

GENTAUR Poland Sp. z o.o.


ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
TEL Gdansk 058 710 33 44 FAX  058 710 33 48              

poland@gentaur.com | Gentaur | Gentaur

Other countries

Österreich +43720880899

Canada Montreal +15149077481

Ceská republika Praha +420246019719

Danmark +4569918806

Finland Helsset +358942419041

Magyarország Budapest +3619980547

Ireland Dublin+35316526556

Luxembourg+35220880274

Norge Oslo+4721031366

Sverige Stockholm+46852503438

Schweiz Züri+41435006251

US New York+17185132983

GENTAUR Italy
SRL IVA IT03841300167
Piazza Giacomo Matteotti, 6
24122 Bergamo Tel 02 36 00 65 93
Fax 02 36 00 65 94
italia@gentaur.com | Gentaur | Gentaur